Fire-rated, acoustic-rated, and robust access panels, riser doors, and loft hatches designed for education environments, where compliance, durability, and acoustic performance are non-negotiable.
Education buildings need access products that maintain fire compartmentation, meet BB93 acoustic standards, withstand heavy daily use, and provide secure maintenance access to concealed services. From school corridors and classrooms to university plant rooms and lecture theatres, every access point must deliver tested performance, long-term durability, and complete compliance documentation for Building Control and DfE sign-off.
Schools, colleges, and universities are high-traffic, high-impact environments. Access products are exposed to daily wear from students, staff, and maintenance teams, so they need to be robust, secure, and tamper-resistant. At the same time, acoustic separation between classrooms, corridors, and plant areas must meet BB93 requirements, and fire compartmentation must be maintained throughout.
Education projects also run to tight programmes, particularly summer refurbishments that need to be completed before the new term. Lead times matter. Getting the wrong product or the wrong documentation slows everything down.
Access panels rated up to 48dB to meet BB93 acoustic requirements for sound insulation between classrooms, corridors, halls, and plant rooms. Independently tested performance that satisfies Building Control.
Access panels and riser doors rated up to 120 minutes, tested to BS EN 1634-1. Maintaining compartmentation in corridors, stairwells, risers, and ceiling voids across schools and university buildings.
Products designed to withstand the daily demands of education environments. Metal-faced panels with powder-coated finishes that resist impact, scratching, and general wear from high-traffic areas.
Locking options to prevent unauthorised access to plant rooms, electrical risers, and service areas. Tamper-resistant solutions that keep students safe and services protected.
Standard products dispatched in 3 to 5 working days. Bespoke orders manufactured in 4 working days. We work to your programme, including tight summer refurbishment windows.
Fire test certificates, acoustic test reports, datasheets, installation guidance, NBS specifications, and BIM objects. Everything required for DfE compliance and Building Control approval.
Fire-rated and acoustic-rated ceiling and wall access for service voids, M&E maintenance, and inspection points in classrooms, corridors, and back-of-house areas.
Fire-rated corridor and stairwell riser access that maintains compartmentation while providing secure maintenance access.
Insulated and fire-rated access to roof spaces and plant areas, meeting Part B, Part L, and BB93 requirements.
Secure, tamper-resistant access to meters and service points in communal areas and corridors.
Acoustic design of schools. Our panels are independently tested to meet the sound insulation requirements between teaching spaces, corridors, and plant areas.
Fire safety and compartmentation. Products tested to BS EN 1634-1 with ratings up to 120 minutes.
Resistance to the passage of sound. Acoustic-rated panels support compliance with Part E separation requirements.
Conservation of fuel and power. Insulated loft hatches and airtight-rated panels support thermal performance requirements.
Documentation and evidence formatted to support sign-off on Department for Education funded projects.
Performance data, standard sizes, bespoke capabilities, and certification details. The complete reference for specifying Rapid Access products on education projects.